Subscribe to Newsletter
Techniques & Tools Liquid Chromatography, Mass Spectrometry, Pharma & Biopharma

Wanted: Native Protein LC-MS

The biologics field is booming and showing no signs of slowing down. As the biotech industry has developed, it has adopted advanced engineering techniques to produce antibody-drug conjugates (ADCs), bispecific monoclonal antibodies, new types of fusion protein scaffolds – and the products are becoming increasingly complex. Yet complexity is no excuse for compromise when it comes to patient safety or lot-to-lot reproducibility, so analytical assays must be up to the challenge of converting complicated biomolecular puzzles into tractable, well-characterized molecules.

There is no one-size-fits-all method for addressing every characterization challenge presented by these new modalities, but it is reasonable to suggest that LC and MS will play a central role. Advances in LC-MS have made it easier than ever to confirm recombinant protein sequences and to investigate product-related impurities. However, LC separations coupled to MS detection have relied largely on denaturing conditions that afford sensitive detection but also restrict our ability to investigate protein conformations and interactions. In short, techniques that couple native separations to MS analysis are needed.

The biologics field is booming and showing no signs of slowing down. As the biotech industry has developed, it has adopted advanced engineering techniques to produce antibody-drug conjugates (ADCs), bispecific monoclonal antibodies, new types of fusion protein scaffolds – and the products are becoming increasingly complex. Yet complexity is no excuse for compromise when it comes to patient safety or lot-to-lot reproducibility, so analytical assays must be up to the challenge of converting complicated biomolecular puzzles into tractable, well-characterized molecules.

There is no one-size-fits-all method for addressing every characterization challenge presented by these new modalities, but it is reasonable to suggest that LC and MS will play a central role. Advances in LC-MS have made it easier than ever to confirm recombinant protein sequences and to investigate product-related impurities. However, LC separations coupled to MS detection have relied largely on denaturing conditions that afford sensitive detection but also restrict our ability to investigate protein conformations and interactions. In short, techniques that couple native separations to MS analysis are needed.

Genuine limitations in reagent and column technologies have long stifled progress. But that’s not to say we’re not moving forward: for example, Bifen Chen, Ying Ge, and colleagues successfully used volatile salts to directly connect hydrophobic interaction chromatography with a mass spectrometer in 2016 (1). They then applied this method to the interrogation of monoclonal antibody samples (2), highlighting the potential for us to selectively separate intact drug isoforms and immediately access MS information for peak identification. This is particularly beneficial to those looking to characterize cysteine-linked ADCs and bispecific antibodies that would otherwise dissociate under denaturing conditions. 

In parallel, Yann LeBlanc and Guillaume Chevreux have started to establish robust, MS-compatible ion exchange separations, including the demonstration that ammonium formate and acetate can be used to carry out salt-mediated pH gradient separations of monoclonal antibodies (3). This seminal work has ushered in a new wave of publications, each describing equally interesting separations – everything from traditional isoelectric focusing to pH gradients supplemented with significant increases in ionic strength (4, 5). But when will these novel methods find their way into routine labs?

Adoption of novel technologies is never easy, but the potential rewards make the venture more than worthwhile. Of course, if we are to develop robust methods that can reproducibly yield easy-to-interpret mass spectra, it will be important to remain scrupulous about reagent quality. And that will require that we learn from those working on high sensitivity trace metal quantitation; here, the most important factor to consider is purity. Certified reagents and high-quality plastics should be used for mobile-phase preparation to avoid the formation of salt adducts. Likewise, the use of different types of volatile salts will require diligent investigation to better understand their effects on electrospray ionization. Nevertheless, by wielding high resolution, MS-compatible native separations, the field will be able to explore new depths of sample characterization; these new separations may be coupled to the detection of native-like gas-phase conformations using a cyclic ion mobility separator (6), or applied to the detection of large megadalton complexes using charge detection MS (7).

The future of native protein LC-MS is bright, and the ever-evolving complexity of biopharmaceuticals gives just cause for investigators to make fast-paced improvements to emerging approaches. Only time will reveal the upper capabilities of these approaches, but I for one am confident and excited to see where such research takes us.  

Receive content, products, events as well as relevant industry updates from The Analytical Scientist and its sponsors.
Stay up to date with our other newsletters and sponsors information, tailored specifically to the fields you are interested in

When you click “Subscribe” we will email you a link, which you must click to verify the email address above and activate your subscription. If you do not receive this email, please contact us at [email protected].
If you wish to unsubscribe, you can update your preferences at any point.

  1. B Chen et al., "Online Hydrophobic Interaction Chromatography - Mass Spectrometry for Top-Down Proteomics", Anal Chem, 88, 1885 (2016). DOI: 10.1021/acs.analchem.5b04285
  2. B Chen et al., "Online hydrophobic interaction chromatography - mass spectrometry for the analysis of intact monoclonal antibodies", Anal Chem, 90, 7135 (2018). DOI: 10.1021/acs.analchem.8b01865.
  3. Y Leblanc et al., "Charge variants characterization of a monoclonal antibody by ion exchange chromatography coupled on-line to native mass spectrometry: Case study after a long-term storage at +5C", J Chromatogr B Analyt Technol Biomed Life Sci, 1048, 130 (2017). DOI: 10.1016/j.chromb.2017.02.017
  4. E Farsang et al., "Optimization of MS-compatible mobile phases for IEX separation of monoclonal antibodies", Chromat Onl, 5, 29 (2019). Available at: bit.ly/30NCw5w
  5. F Fűssl et al., "Charge variant analysis of monoclonal antibodies using direct coupled pH gradient cation exchange chromatography to high-resolution native mass spectrometry", Anal Chem, 90, 4667 (2018). DOI: 10.1021/acs.analchem.7b05241
  6. K Giles et al., "A cyclic ion mobility-mass spectrometry system", Anal Chem, 91, 8564 (2019). DOI: 10.1021/acs.analchem.9b01838
  7. EE Pierson et al., "Resolving adeno-associated viral particle diversity with charge detection mass spectrometry", Anal Chem, 88, 6718 (2016). DOI: 10.1021/acs.analchem.6b00883
About the Author
Matthew A. Lauber

Waters Corporation, Milford, Massachusetts, USA.

Related Application Notes
Safer AAV Analysis with Non-toxic AEX Method

| Contributed by Tosoh

Non-targeted profiling of polar metabolites in human plasma

| Contributed by YMC

High Sensitivity allergen detection in wine samples

| Contributed by YMC

Related Product Profiles
The fine Art of Method Development

| Contributed by Shimadzu Europa

Higher Peaks – Clearly.

| Contributed by Shimadzu Europa

Compact with countless benefits

| Contributed by Shimadzu Europa

Register to The Analytical Scientist

Register to access our FREE online portfolio, request the magazine in print and manage your preferences.

You will benefit from:
  • Unlimited access to ALL articles
  • News, interviews & opinions from leading industry experts
  • Receive print (and PDF) copies of The Analytical Scientist magazine

Register