Conexiant
Login
  • The Analytical Scientist
  • The Cannabis Scientist
  • The Medicine Maker
  • The Ophthalmologist
  • The Pathologist
  • The Traditional Scientist
The Analytical Scientist
  • Explore

    Explore

    • Latest
    • News & Research
    • Trends & Challenges
    • Keynote Interviews
    • Opinion & Personal Narratives
    • Product Profiles
    • App Notes

    Featured Topics

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy

    Issues

    • Latest Issue
    • Archive
  • Topics

    Techniques & Tools

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy
    • Microscopy
    • Sensors
    • Data and AI

    • View All Topics

    Applications & Fields

    • Clinical
    • Environmental
    • Food, Beverage & Agriculture
    • Pharma and Biopharma
    • Omics
    • Forensics
  • People & Profiles

    People & Profiles

    • Power List
    • Voices in the Community
    • Sitting Down With
    • Authors & Contributors
  • Business & Education

    Business & Education

    • Innovation
    • Business & Entrepreneurship
    • Career Pathways
  • Events
    • Live Events
    • Webinars
  • Multimedia
    • Video
Subscribe
Subscribe

False

The Analytical Scientist / App Notes / 2015 / A Comparison of Two Solid Phase Extraction Methods for the Analysis of Polyaromatic Hydrocarbons in Butter

A Comparison of Two Solid Phase Extraction Methods for the Analysis of Polyaromatic Hydrocarbons in Butter

09/09/2015

Share

Featured Image
Background

Polyaromatic hydrocarbons (PAHs) are ubiquitous in the environment, resulting from both natural and manmade sources of combustion. Farm animals, such as cows, can become exposed to them through both consumption of contaminated feed and water, and inhalation of contaminated atmosphere.¹ Consequently, these compounds can be present in dairy products produced from cow’s milk such as cheese and butter. Analysis of these compounds in butter can pose a special challenge due to the high fat content and the lipophilic nature of PAHs. Recovery of the PAHs often results in coextraction of the fatty matrix. In this application, Supelclean™ EZ-POP NP SPE was used as part of an extraction and cleanup procedure for the analysis of PAHs in butter by GC/MS in selected ion mode (SIM). After EZ-POP NP extraction, a secondary cleanup was done using silica gel. This produced an extract with low GC/MS background that could be analyzed on a single quadrupole instrument. The method was compared with an alternative sample preparation approach using a large silica gel SPE cartridge, and was found to produce better recoveries and lower background.

Experimental

Butter was spiked at 20 ng/g with 28 different PAHs, containing 2-6 rings in their structures. The butter was melted and 1 g was diluted to 1 mL in cyclohexane. After mixing, sediment was allowed to settle and the resulting supernatant was drawn off for extraction. Replicate samples were extracted in two separate sets using the procedures outlined in Tables 1 and 2. Analysis was performed by GC/MS-SIM using the conditions listed in Table 3. GC/MS conditions were optimized for response and peak shape of the PAHs, especially those with 5 and 6 rings. Quantitation was performed using 5-point calibration curves prepared in unspiked butter extract. Separate curves were prepared for each set of samples and internal standard correction was used in calculating response.

>> Download the full Application Note as PDF

Newsletters

Receive the latest pathologist news, personalities, education, and career development – weekly to your inbox.

Newsletter Signup Image

Explore More in Pathology

Dive deeper into the world of pathology. Explore the latest articles, case studies, expert insights, and groundbreaking research.

False

Advertisement

Recommended

False

Related Content

NIR on the Range: Grazing Animal Nutrition
NIR on the Range: Grazing Animal Nutrition

January 16, 2015

Portable NIR spectroscopy of grazing animal feces ...

Oceans Help Predict a Wave of Climate Change
Oceans Help Predict a Wave of Climate Change

January 16, 2015

A fluorescence-based assay helps study carbon fixa...

Why They Choose FDGSi
Why They Choose FDGSi

February 17, 2015

Find out why companies choose F-DGSi

Comparison of Biotage® Extrahera™ vs. Manual Sample Processing Using a Vacuum Manifold
Comparison of Biotage® Extrahera™ vs. Manual Sample Processing Using a Vacuum Manifold

February 27, 2015

Comparison of Biotage® Extrahera™ vs...

False

The Analytical Scientist
Subscribe

About

  • About Us
  • Work at Conexiant Europe
  • Terms and Conditions
  • Privacy Policy
  • Advertise With Us
  • Contact Us

Copyright © 2025 Texere Publishing Limited (trading as Conexiant), with registered number 08113419 whose registered office is at Booths No. 1, Booths Park, Chelford Road, Knutsford, England, WA16 8GS.