Conexiant
Login
  • The Analytical Scientist
  • The Cannabis Scientist
  • The Medicine Maker
  • The Ophthalmologist
  • The Pathologist
  • The Traditional Scientist
The Analytical Scientist
  • Explore

    Explore

    • Latest
    • News & Research
    • Trends & Challenges
    • Keynote Interviews
    • Opinion & Personal Narratives
    • Product Profiles
    • App Notes

    Featured Topics

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy

    Issues

    • Latest Issue
    • Archive
  • Topics

    Techniques & Tools

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy
    • Microscopy
    • Sensors
    • Data and AI

    • View All Topics

    Applications & Fields

    • Clinical
    • Environmental
    • Food, Beverage & Agriculture
    • Pharma and Biopharma
    • Omics
    • Forensics
  • People & Profiles

    People & Profiles

    • Power List
    • Voices in the Community
    • Sitting Down With
    • Authors & Contributors
  • Business & Education

    Business & Education

    • Innovation
    • Business & Entrepreneurship
    • Career Pathways
  • Events
    • Live Events
    • Webinars
  • Multimedia
    • Video
Subscribe
Subscribe

False

The Analytical Scientist / App Notes / 2020 / An End-To-End Workflow for Quantitative Screening of Multiclass, Multiresidue Veterinary Drugs in Meat Using the Agilent 6470 Triple Quadrupole LC/MS

An End-To-End Workflow for Quantitative Screening of Multiclass, Multiresidue Veterinary Drugs in Meat Using the Agilent 6470 Triple Quadrupole LC/MS

11/11/2020

Share

Featured Image

Authors

Siji Joseph, Aimei Zou, Chee Sian Gan, Limian Zhao, and Patrick Batoon Agilent Technologies, Inc.

A comprehensive LC/MS/MS workflow was developed for targeted screening or quantitation of 210 veterinary drug residues in animal muscle prepared for human consumption, with the intention to accelerate and simplify routine laboratory testing. The workflow ranged from sample preparation through chromatographic separation, MS detection, data processing and analysis, and report generation. The workflow performance was evaluated using three muscle matrices—chicken, pork, and beef— and was assessed on two different Agilent triple quadrupole LC/MS models (an Agilent 6470 and a 6495C triple quadrupole LC/MS). A simple sample preparation protocol using Agilent Captiva EMR—Lipid cartridges provided efficient extraction and matrix cleanup. A single chromatographic method using Agilent InfinityLab Poroshell 120 EC-C18 columns with a 13-minute method delivered acceptable separation and retention time distribution across the elution window for reliable triple quadrupole detection and data analysis.

Workflow performance was evaluated based on evaluation of limit of detection (LOD), limit of quantitation (LOQ), calibration curve linearity, accuracy, precision, and recovery, using matrix-matched spike samples for a range from 0.1 to 100 μg/L. Calibration curves were plotted from LOQ to 100 μg/L, where all analytes demonstrated linearity R2 >0.99. Instrument method accuracy values were within 73 to 113%. Target analytes response and retention time %RSD values were ≤19% and ≤0.28% respectively. Analyte recovery and reproducibility at three levels of fortified quality control (QC) samples—1, 10, and 25 μg/kg in meat—were used to validate the method applicability for confident routine screening of veterinary drugs. The recovery repeatability (intrabatch technical replicates) and recovery reproducibility (interbatch technical replicates) were calculated using QC samples, and the results were within acceptable limits of 20 and 32%, respectively.1 The workflow method performance results across the chicken, beef, and pork muscle matrices showed excellent overlap, and confirm the method applicability for routine multiresidue screening in various animal origin matrices.

>> Download the Full Application Note as a PDF

Newsletters

Receive the latest pathologist news, personalities, education, and career development – weekly to your inbox.

Newsletter Signup Image

Explore More in Pathology

Dive deeper into the world of pathology. Explore the latest articles, case studies, expert insights, and groundbreaking research.

False

Advertisement

Recommended

False

Related Content

Detection of residual pesticides on fruits and vegetables using Portability™ miniature mass spectrometer
Detection of residual pesticides on fruits and vegetables using Portability™ miniature mass spectrometer

June 9, 2020

Mass spectrometry can be now deployed for onsite pesticide screening in real time...

Routine monitoring of airborne VOCs using TD–GC×GC–TOF MS/FID
Routine monitoring of airborne VOCs using TD–GC×GC–TOF MS/FID

January 15, 2020

The identification and quantitation of volatile organic pollutants in air can be challenging, largely because of the complexity of the samples...

Quantifying trace odorants in water by GC–MS with trap-based preconcentration
Quantifying trace odorants in water by GC–MS with trap-based preconcentration

January 20, 2020

Assessing SPME and high‑capacity sorptive extracti...

Using Self-Aware Agilent InfinityLab LC/MSD iQ to Measure Trace-Level Impurities in a Brand Versus Generic Medication
Using Self-Aware Agilent InfinityLab LC/MSD iQ to Measure Trace-Level Impurities in a Brand Versus Generic Medication

January 22, 2020

This study presents a method for comparison of related impurities in a brand and a generic over-the-counter (OTC) acetaminophen drug...

False

The Analytical Scientist
Subscribe

About

  • About Us
  • Work at Conexiant Europe
  • Terms and Conditions
  • Privacy Policy
  • Advertise With Us
  • Contact Us

Copyright © 2025 Texere Publishing Limited (trading as Conexiant), with registered number 08113419 whose registered office is at Booths No. 1, Booths Park, Chelford Road, Knutsford, England, WA16 8GS.