Conexiant
Login
  • The Analytical Scientist
  • The Cannabis Scientist
  • The Medicine Maker
  • The Ophthalmologist
  • The Pathologist
  • The Traditional Scientist
The Analytical Scientist
  • Explore

    Explore

    • Latest
    • News & Research
    • Trends & Challenges
    • Keynote Interviews
    • Opinion & Personal Narratives
    • Product Profiles
    • App Notes

    Featured Topics

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy

    Issues

    • Latest Issue
    • Archive
  • Topics

    Techniques & Tools

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy
    • Microscopy
    • Sensors
    • Data and AI

    • View All Topics

    Applications & Fields

    • Clinical
    • Environmental
    • Food, Beverage & Agriculture
    • Pharma and Biopharma
    • Omics
    • Forensics
  • People & Profiles

    People & Profiles

    • Power List
    • Voices in the Community
    • Sitting Down With
    • Authors & Contributors
  • Business & Education

    Business & Education

    • Innovation
    • Business & Entrepreneurship
    • Career Pathways
  • Events
    • Live Events
    • Webinars
  • Multimedia
    • Video
Subscribe
Subscribe

False

The Analytical Scientist / App Notes / 2015 / Extraction of Buprenorphine and Norbuprenorphine from Oral Fluid Using EVOLUTE® EXPRESS CX Prior to LC-MS/MS Analysis

Extraction of Buprenorphine and Norbuprenorphine from Oral Fluid Using EVOLUTE® EXPRESS CX Prior to LC-MS/MS Analysis

11/13/2015

Share

Featured Image
Introduction

This application note describes a simple and robust mixedmode cation exchange solid phase extraction protocol using EVOLUTE® EXPRESS CX 96-well plates for the extraction of buprenorphine and norbuprenorphine from oral fluid. Excellent extract cleanliness allows quantitation of the analytes across the range 0.1 ng/mL to 100 ng/mL using LC-MS/MS.

Figure 1. Structures of Buprenorphine and Norbuprenorphine.

EVOLUTE EXPRESS solid phase extraction products combine powerful EVOLUTE sorbent chemistry with enhanced ‘EXPRESS’ components. EVOLUTE EXPRESS products dramatically improve flow characteristics, and enhance sample preparation productivity. By truly eliminating the need for column conditioning and equilibration, samples can be prepared using a simple, fast load-wash-elute procedure. Analytes Buprenorphine, Norbuprenorphine Internal Standards Buprenorphine D4, Norbuprenorphine D3

Sample Preparation Procedure

Format: EVOLUTE® EXPRESS CX 10 mg fixed well plate, part number 601-0010-PX01 Sample Pre-treatment Add 100 μL of sample (calibrator, QC or patient) to 900 μL of 0.1% aqueous formic acid. Either add an appropriate amount of internal standard separately or mix internal standard into formic acid pre-treatment solution prior to adding to sample. Sample Loading Load a 1 mL volume of pre-treated sample into each well at a flow rate of 1 mL/min (~10–12 drops/min).

>> Download the full Application Note as PDF

Newsletters

Receive the latest pathologist news, personalities, education, and career development – weekly to your inbox.

Newsletter Signup Image

Explore More in Pathology

Dive deeper into the world of pathology. Explore the latest articles, case studies, expert insights, and groundbreaking research.

False

Advertisement

Recommended

False

Related Content

NIR on the Range: Grazing Animal Nutrition
NIR on the Range: Grazing Animal Nutrition

January 16, 2015

Portable NIR spectroscopy of grazing animal feces ...

Oceans Help Predict a Wave of Climate Change
Oceans Help Predict a Wave of Climate Change

January 16, 2015

A fluorescence-based assay helps study carbon fixa...

Why They Choose FDGSi
Why They Choose FDGSi

February 17, 2015

Find out why companies choose F-DGSi

Comparison of Biotage® Extrahera™ vs. Manual Sample Processing Using a Vacuum Manifold
Comparison of Biotage® Extrahera™ vs. Manual Sample Processing Using a Vacuum Manifold

February 27, 2015

Comparison of Biotage® Extrahera™ vs...

False

The Analytical Scientist
Subscribe

About

  • About Us
  • Work at Conexiant Europe
  • Terms and Conditions
  • Privacy Policy
  • Advertise With Us
  • Contact Us

Copyright © 2025 Texere Publishing Limited (trading as Conexiant), with registered number 08113419 whose registered office is at Booths No. 1, Booths Park, Chelford Road, Knutsford, England, WA16 8GS.