Conexiant
Login
  • The Analytical Scientist
  • The Cannabis Scientist
  • The Medicine Maker
  • The Ophthalmologist
  • The Pathologist
  • The Traditional Scientist
The Analytical Scientist
  • Explore

    Explore

    • Latest
    • News & Research
    • Trends & Challenges
    • Keynote Interviews
    • Opinion & Personal Narratives
    • Product Profiles
    • App Notes

    Featured Topics

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy

    Issues

    • Latest Issue
    • Archive
  • Topics

    Techniques & Tools

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy
    • Microscopy
    • Sensors
    • Data and AI

    • View All Topics

    Applications & Fields

    • Clinical
    • Environmental
    • Food, Beverage & Agriculture
    • Pharma and Biopharma
    • Omics
    • Forensics
  • People & Profiles

    People & Profiles

    • Power List
    • Voices in the Community
    • Sitting Down With
    • Authors & Contributors
  • Business & Education

    Business & Education

    • Innovation
    • Business & Entrepreneurship
    • Career Pathways
  • Events
    • Live Events
    • Webinars
  • Multimedia
    • Video
Subscribe
Subscribe

False

The Analytical Scientist / App Notes / 2018 / Simultaneous Extraction of Aldosterone and Angiotensin I and II from Human Plasma Using EVOLUTE® EXPRESS ABN Prior to LC/MS Analysis

Simultaneous Extraction of Aldosterone and Angiotensin I and II from Human Plasma Using EVOLUTE® EXPRESS ABN Prior to LC/MS Analysis

11/19/2018

Share

Featured Image
Introduction

This application note describes the simultaneous extraction of aldosterone and angiotensin from human plasma using the EVOLUTE® EXPRESS ABN Solid Phase Extraction plates prior to LC-MS/MS analysis.

Plasma renin activity (PRA) determination is used in the diagnosis of primary aldosteronism, an important cause of secondary hypertension (high blood pressure). Concomitant measurement of both aldosterone and angiotensin (converted from renin over a time range) in the plasma sample is required. Traditionally the analysis of these species is performed separately. This application note describes the simultaneous extraction of aldosterone at low (< 25pg/mL) concentration and angiotensin I and II from plasma, with the potential to improve throughput and reduce time and costs.

The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 80% with RSDs lower than 5% for all analytes using LC-MS/MS.

Figure 1. Structures of Aldosterone, Angiotensin I and Angiotensin II .

>> Download the full Application Note as PDF

Newsletters

Receive the latest analytical scientist news, personalities, education, and career development – weekly to your inbox.

Newsletter Signup Image

Explore More in Analytical Science

Dive deeper into the analytical science. Explore the latest articles, case studies, expert insights, and groundbreaking research.

False

Advertisement

Recommended

False

Related Content

Download the latest Lab Trends Report
Download the latest Lab Trends Report

January 8, 2018

To better understand the view from the lab, we asked nearly 500 scientists some searching questions...

Confocal Raman Imaging – Depth profiling of polymer films and coatings
Confocal Raman Imaging – Depth profiling of polymer films and coatings

January 16, 2018

This application note demonstrates how confocal Raman imaging is capable of acquiring depth profiles of polymers coatings that allow individual layers to be distinguished and measured...

Real-Time Speciation of Ethylbenzene from the Xylenes Using Direct MS
Real-Time Speciation of Ethylbenzene from the Xylenes Using Direct MS

January 18, 2018

This application note describes how selected ion flow tube mass spectrometry (SIFT-MS) readily achieves real-time speciation of the xylenes from ethylbenzene...

Monitoring and Controlling the Electrode Particle Characteristics and Viscosity of Battery Slurries
Monitoring and Controlling the Electrode Particle Characteristics and Viscosity of Battery Slurries

January 26, 2018

Using Morphologi G3 to monitor and control the electrode particle characteristics and viscosity of battery slurries...

False

The Analytical Scientist
Subscribe

About

  • About Us
  • Work at Conexiant Europe
  • Terms and Conditions
  • Privacy Policy
  • Advertise With Us
  • Contact Us

Copyright © 2025 Texere Publishing Limited (trading as Conexiant), with registered number 08113419 whose registered office is at Booths No. 1, Booths Park, Chelford Road, Knutsford, England, WA16 8GS.