No Single Method Fits Every Nitrosamine
The expanding range of nitrosamine impurities is making product-specific analytical method development increasingly important, according to a review of pharmaceutical testing approaches reported between 2020 and 2025.
GC-MS and LC-MS remain the principal platforms for trace-level testing, but differences in volatility, polarity, thermal stability, and molecular structure mean neither suits every impurity or pharmaceutical matrix.
GC methods generally suit small, volatile nitrosamines. LC-MS is better suited to nonvolatile, thermally unstable, or structurally complex compounds, including nitrosamine drug substance-related impurities (NDSRIs), which are structurally related to individual active pharmaceutical ingredients.
Sample preparation remains critical because drug-product ingredients can affect extraction and suppress or enhance ionization. The review also identifies limited availability of NDSRI reference standards as an obstacle to routine testing.
Complementary approaches, including total nitrosamine assays and predictive nitrosation experiments, may support screening and risk assessment, but require compound-specific confirmation.
For laboratories, method selection therefore depends on the target impurity, dosage form, required sensitivity, and available instrumentation. Source
How Sustainable Are Pharmaceutical Nitrosamine Tests?
None of the main mass spectrometry methods used to test pharmaceuticals for nitrosamine impurities performs strongly against every measure of analytical sustainability, according to a comparison of European and US pharmacopeial procedures.
The researchers assessed seven pharmacopeial methods and an SFC-MS/MS method using the Analytical GREEnness Metric, which considers factors including solvent consumption, waste, energy use, and reagent safety. Overall scores ranged from 0.45 to 0.54, with strengths in one area offset by drawbacks elsewhere.
Liquid-injection GC methods required hazardous extraction solvents, while headspace sampling simplified preparation. However, the GC methods still relied on helium. LC procedures varied considerably in solvent consumption and runtime.
The SFC-MS/MS method separated 16 nitrosamines within four minutes using supercritical carbon dioxide as its principal mobile phase, but required trifluoroacetic acid, reducing its operator-safety score.
All methods scored poorly for energy consumption because they relied on mass spectrometry. The findings highlight the need to assess sustainability beyond solvent use, balancing analytical performance with waste, energy demand, and staff safety. Source
FDA Recall Data Show Scale of Pharmaceutical Nitrosamine Problem
Angiotensin receptor blockers and metformin accounted for the largest numbers of pharmaceutical lots recalled in the US because of nitrosamine contamination between July 2018 and March 2025, according to a retrospective regulatory analysis.
Researchers examined FDA recall records and nitrosamine resources, identifying 1,246 recalled lots of angiotensin receptor blockers and 281 lots of metformin products. These figures represent product lots, rather than individual recall events or patients affected.
Losartan accounted for 27 percent of recalled angiotensin receptor blocker lots. Among metformin products, 500 mg extended-release tablets accounted for 200 lots, or 71 percent of the total.
The analysis also traces the growing involvement of nitrosamine drug substance-related impurities, alongside the small nitrosamines associated with initial recalls.
Potential sources included manufacturing conditions, nitrite-containing excipients, packaging, and changes during storage. The findings support extending risk assessment beyond active ingredient synthesis to formulation and shelf life, with sensitive analytical testing and tighter control of raw materials among the measures proposed to reduce future recalls. Source
LC-MS/MS Tracks Nitrosamine Increase During Drug Shelf Life
An LC-MS/MS investigation of 12 marketed-product batches detected a nitrosamine impurity that increased during storage, highlighting the value of testing stability samples alongside newly manufactured batches.
Researchers developed three complementary UPLC-APCI-MS/MS methods to screen for 17 small-molecule nitrosamines in an uncoated tablet. Adjusting mobile-phase pH and probe temperature improved sensitivity, limited thermal degradation, and separated impurities from the active ingredient. The product and detected impurities were not identified for confidentiality reasons.
Testing covered batches manufactured between 2021 and 2024, including release samples and material stored at 25 °C and 60 percent relative humidity.
One impurity was present in every batch and increased from below 10 percent of its acceptable limit at release to above 30 percent after 24 months. It remained below the full acceptable limit throughout shelf life.
The product remained compliant, but the increase meant routine quantitative testing remained necessary. The authors suggest that API degradation could explain the trend, with storage conditions and packaging potential subjects for further investigation. Source
LC-MS Study Links Nitrosamines and Sphingolipids to Esophageal Cancer
Researchers have identified associations among urinary nitrosamine levels, disrupted sphingolipid metabolism, and esophageal squamous cell carcinoma (ESCC), using LC-MS-based measurements from 241 participants.
The study combined urinary nitrosamine analysis with untargeted and targeted serum metabolomics. The findings suggest that certain sphingolipids could help researchers investigate the biological links between nitrosamine exposure and esophageal disease, although the cross-sectional design cannot establish cause and effect.
The researchers quantified nine nitrosamines in urine using UPLC-MS/MS. Serum samples were initially profiled by UHPLC coupled with time-of-flight mass spectrometry, before selected sphingolipids were quantified using multiple reaction monitoring.
Urinary nitrosamine profiles differed among the disease groups.
Metabolomic analysis identified sphingolipid metabolism as one of the pathways most consistently altered with disease progression.
The team also assessed the metabolites as potential biomarkers. Within the study population, sphingosine-1-phosphate showed moderate ability to distinguish each disease group from healthy controls. Source